1. Product description
  
     FS00208 Sensor is a Multi in one sensor which can simultaneously monitor the concentration of particulate matter, formaldehyde, temperature and humidity in the air. Based on the principle of laser scattering, the monitoring of particulate matter concentration can continuously collect and calculate the number of suspended particulate matter with different particle sizes in the air per unit volume, that is, the distribution of particulate matter concentration, and then convert it into mass concentration. The monitoring of formaldehyde concentration is based on the principle of electrochemistry and has the characteristics of high accuracy and stability. Temperature and humidity sensors are imported from Switzerland. Particulate matter concentration, formaldehyde concentration, temperature and humidity are combined and output in the form of universal digital interface.
      This sensor can be embedded in all kinds of instruments and apparatuses or environmental improvement equipment that are related to air quality and provide timely and accurate concentration data.

2. The characteristic of sensor

. All-round shielding design, anti-interference ability, the same side of the inlet and outlet, customers do not need to duct design
. Dust minimal resolution 0.3 microns
. Fomaldehyde minimum resolution 0.001 mg/m3
. Ultra-thin thickness, Ultra-quiet 
. Zero error alarm rate
. Real-time response
. Accurate data
. Long service life
. Real-time output of formaldehyde and temperature and humidity data
 
3. Main application

. Air Quality monitors, portable instrument, air cleaner
. Fresh air ventilator, air conditioning, equipment for smart home
. Hospitals, hotels , schools and other public places

4. Technique index

ParameterIndexUnit
Particle size range0.3~10μm
Technical efficiency50% @ 0.3   98%@>=0.5um
Measurement rangePM1.0:  0 ~ 1,000μg/m³
PM2.5:  0 ~ 1,000μg/m³
PM10:  0 ~ 1,000μg/m³
Temperature:  -40 ~ 90 ℃
Humidity:   0-99 %RH
Formaldehyde: 0-3ppm

Effective rangePM1.0:  0 ~ 1000μg/m³
PM2.5:  0 ~ 1000μg/m³
PM10:  0 ~ 1000μg/m³
Temperature:  -40 ~ 90 ℃
Humidity:   0-99 %RH
Formaldehyde: 0-3ppm

Maximum consistency error for PM1.0&PM2.5&PM100 ~ 100μg/m³, ±10μg/m³
101 ~ 1,000μg/m³, ±10% reading

Maximum errorTemperature:   ±0.3℃
Humidity:      ±3%RH
Formaldehyde:  <±10%FS 

resolutionTemperature:   0.01℃
   Humidity:     0.1%RH
PM1.0/2.5/10:   1μg/m³
Formaldehyde:   0.001ppm

DC5.0±0.1V
Response time≤10S
Ripple<50mv
Maximum operating current100mA
Standby current≤200uA
Data interface voltageL <0.8@3.3   H >2.7@3.3V
Operating temperature range-10~+50
Storage temperature range-30 ~ 60
Operating humidity range0~99%(non-condensing)RH
MTTFLaser  >30000 hr (continuous turn on)
Formaldehyde  2 year (relatively clean air)

Reference size48×37×17mm
 

Table 1: technical indicators

*NB: Sensor performance tested under standard conditions of 293K, 1atm., 35%RH. Sensors are best stored at 20°C in sealed plastic bags for maximum storage life.
 