Like

Reference Multimeter

  • Product model8588A
  • Product brand FLUKE
  • Apply area:Marine Equipment,Petrochemical Industry,Electric Power,Light Industry,Aerospace/Marine,Special Industry,Equipment Manufacturing,Inter-city Rail Transport/Metro,Instrumentation and Measurement,Automation Cntrol,semiconductor,Warehouse,Nuclear Power,Metallurgy/Steel Industry,HVAC,Machine Engineering,Telecommunication,Smart Phone,Smart Home,Oil-fueled Automotive

FLUKE Corporation

  

Product Details Product specification download

8588A key features and performance

DC voltage
  • 100 mV to 1000 V, (1050V max)
  • 2.02x full scale
  • Maximum resolution: 1 nV
  • 2.7 μV/V (95 %) 3.5 μV/V (99 %), 1 year
  • 0.5 μV/V (95 %) 0.65 μV/V (99 %), 24 hour stability
  • 0 to 10 s reading aperture (200 ns resolution)
     
DC current
  • 10 uA to 30 A (8588A only; 2 A for 8558A)
  • 2.02x full scale
  • Maximum resolution: 1 pA
  • 6.5 μA/A (95 %), 8.4 μA/V (99 %), 1 year
  • 0 ns to 100 s reading aperture
 
AC voltage
  • 10 mV to 1000 V, 1 Hz to 10 MHz, (1050 Vrms max)
  • 2.02x full scale Vpp, 1.2x full scale Vrms
  • Maximum resolution: 1 nV
  • 60 μV/V (95 %), 77 μV/V (99 %), 1 year
 
AC current
  • 10 uA to 30 A (8588A only; 2 A for 8558A)
  • 2.02x full scale Vpp, 1 Hz to 100 kHz 1.2x full scale Vrms
  • Maximum resolution: 1 pA
  • 250 μA/A (95 %), 323 μA/V (99 %), 1 year
 
Resistance
  • 1Ω to 10 GΩ (20 GΩ max)
  • 2.02x full scale
  • Maximum resolution: 10 nΩ
  • 7 μΩ/Ω (95 %), 9 μΩ/Ω (99 %), 1 year
  • Low current mode, high voltage mode and current-reversal Tru Ohms™
 
Digitize V
  • 100 mV to 1000 V, (1050 V max)
  • 2.02x full scale
  • Maximum resolution: 18 bits
  • 5 mega-samples per second sample rate
  • Up to 20 MHz bandwidth
     
Digitize I
  • 10 μA to 30 A (8588A only; 2A for 8558A)
  • 2.02x full scale
  • Maximum resolution: 18 bits
  • 5 mega-samples per second sample rate
  • Up to 4 MHz bandwidth
     
Frequency or period
  • Voltage, up to 10 MHz
  • Current, up to 100 kHz
  • Frequency up to 100 MHz on BNC
  • 0.5 μHz/Hz, 1 year
     
Capacitance
  • 1 nF to 100 mF
  • 400 μF/F, 1 year
     
Temperature
  • PRT and thermocouple
  • 5 mK PRT, 25 mK TC - 1 year
     
RF power
  • Rhode & Schwarz NRP series DC I and AC I external shunt

DC I and AC I external shunt

  • A40B and any other external shunt
 
Reading speed
  • 1 reading /s @ 8.5 digit into memory
  • 100,000 readings /s @ 4.5 digit into memory
  • Up to 5,000,000 (5 MS/s) readings /s into volatile memory in digitize V and I
  • Up to 500,000 readings/s transfer through USB in binary format
 
Measurement memory
  • 15 million readings volitile
  • 7.5 million readings with time stamp volitile
  • 16 GB non-volitile
 
GPIB, USBTMC, Ethernet
  • Native SCPI compliant remote commands
  • 8508A and 3458A emulation mode
  • Fully support MET/CAL™ calibration procedures library in Fluke 8508A emulation
  • IVI driver
  • USB thumb drive for convenient data transfer in .csv format
 
Trigger mechanisms
  • Manual trigger
  • External BNC Trig In and Trig Out
  • Internal or level trigger
  • Timer trigger
  • Epoch trigger
  • Line trigger
  • BUS trigger
     
CE and CSA compliant