F1031 micro flow sensor adopts thermodynamic principle
to detect the gas flow, and it has high accuracy and good
repeatability. The built-in temperature sensor makes the
product has the function of professional temperature
compensation calibration. At the same time, the output is
linear analog voltage which is convenient to use.
Features
Latest MEMS Sensor chip technology
High accuracy, quick response, good repeatability
Detection micro flow accurately
It is calibrated completely and temperature compensated
Main Applications
Industrial process control
Air and environment protection
Portable detector
Technical Parameters
Stable1.Technical Parameters
Model
F1031
Measuring Range① 50、100、150、200、300 SLM②
Min Typical Max Unit
Full Scale Output
4.90
5.00
5.10
V
Zero Output
0.96
1.00
1.04
V
Output Impedance
-
200
-
Ω
Working Voltage
7.0
10.0
14.0
V
Working Current
15
25
30
mA
Accuracy
-
±1.5
±2.5
%F.S
Repeatability
-
±0.3
±0.5
%F.S
Annual Drift
-
±0.1
±0.5
%F.S
Pressure range
-
-
100
kPa
Response Time③
55
50
55
ms
Working Temp.④
-25
65
℃
Storage Temp.
-40
90
℃
Pin
Function
1(black or gray)
GND
2(red)
VCC
3(yellow)
OUT