Please:Sign In
UGT-C5 Combustible gas sensor
ShenZhen Singoan Electronic Technogy Co.,Ltd
China Guangdong Province Shenzhen City
FEATURES
·Good long-term stability
·Excellent repeatability
·Superior linearity
·Strong vibration resistance
·Excellent anti-poisoning ability
ELECTRICAL
Supply Voltage DC2.5±0.1V
Working current DC170~190mA(at 2.5V)
Power consumption <500mW
Zero point output ±25mV
Sensitivity 18~32mV / 20%LEL methane
ENVIRONMENTAL
Operating Temperature Range -40~+70℃
Operating Humidity Range Continuity 15~90%RH
Intermittent 0~99%RH
STORAGE ENNIRONMENT
Recommended Storage Temp -20~+50℃
Relative humidity Below 95% RH
(without condensation)
TECHNICAL SPECIFICATION
Measurement Range 0~100%LEL
Gas Detected Most combustible gases
& vapours
Accuracy ±3%LEL
Zero drift ±1%LEL
Linearity (0~100%LEL) ±3%(Calibrate at 60%LEL)
Full range deviation ±5%LEL
Response time 50%LEL T90<10s
Operating Principle Catalytic combustion
Recovery time 15s
Operating life 5 years (in clean air)
Warranty period 2 years(from the date of shipment)
Orientation
When the orientation of the sensor at the detection
end and compensation end changes (the sensor
rotates 360 °vertically), the change of the sensor output signal is ± 0.5% LEL