Please:Sign In
Low-power consumptioninfrared combustible gas sensor
IR-X-D low-power infrared sensors are mainly used for wireless combustible gas alarms and portable instruments requiring long endurance.
1: Ultra-low power consumption: The default mode is 1.2mw, and the ultra-low power consumption mode is as low as 0.6mw, which meets the requirements of long endurance of the equipment.
2: Multiple target gases: support calibration of multiple HC gases, CH4, C2H6, C3H8, i-C4H10 and other dual-gas combinations
3: Industrial design: -41 ℃ ~ 71 ℃ temperature compensation, metal gold-plated shell, suitable for various outdoor industrial environments
Detection principle: non-dispersive infrared absorption (NDIR)
Detection gas: HC alkane gas
Detection range: Methane: 0 ~ 5% VOL (compatible with 0 ~ 100% VOl) Ethane: 0-3% VOL Propane: 0-2.1% VOl Isobutane: 0 ~ 1.8% VOL (default calibration compensation coefficient of CH4 and C4H10)
Measurement error: ± 3% LEL * 1
Operating voltage: 3.0 V ~ 5.0 V * 1 (3.6 V recommended)
Average power: < 1.2mW (average power consumption 3.3 V 360uA, minimum 180uA can be switched by command) * 1
Working temperature: -40 ℃ ~ 70 ℃
Working humidity: 0 ~ 98% RH (no condensation)
Warm-up time: 30 s
Response time: T90 < 20s * 2
Communication interface: UART, 1Hz (maximum)
Optical mirror: gold-plated film
Life expectancy: 8-10 years (clean air)
Degree of protection: IP 54
Explosion-proof sign: Ex ia lIC T4 Ga
Intrinsic safety parameters: UI = 5V Li = 400mA Ci = 38 uF Li = 0mH Pi = 0.5W