Please:Sign In
Back Perforated DC sensor
| Parameters | Symbol | Value | unit | 
| Primary rated current | Ipn | 100,200,300,400,500,600 | A | 
| Secondary rated voltage | Vsn | 4 | V | 
| Primary maximum current | Ip | 1.2 Ipn | A | 
| Secondary output voltage | Vo | 4 .0* (I / Ipn) | V | 
| Load impedance | RL | ≥10 | kΩ | 
| Supply voltage | Vc | ±12(±5%) | V | 
| Static current consumption(@±12V, I=0A) | IC | ≤5 | mA | 
| Maximum current consumption(@±12V, I=Ip) | Im | ≤145 | mA | 
| Total accuracy(@25℃) | XG | ≤0.5FS | % | 
| Linearity(@25℃) | εL | ≤0.2FS | % | 
| Zero offset voltage(I=0A,@25℃) | VOE | ≤+1 | mV | 
| Zero temperature drift(I=0A,@-40~85℃) | VOT | <0.1 | mV/℃ | 
| Hysteresis offset voltage(@I=0A, after 1*IPN) | VOH | ≤±1 | mV | 
| Response time(@90% Ipn) | Tra | ≤5 | μS | 
| Bandwidth(@10%Ipn, -3dB) | BW | DC~20 | kHz |